GloCyte Automated Cell Counter | Advanced Instruments

GloCyte Automated CSF Cell Counter

hey
hey
hey
hey
Highlighted Features:
  • Able to detect down to 1 cell/µL
  • Delivers TNC and RBC results in less than 5 minutes
  • Easy to operate; everything is on one screen
  • Interactive software makes troubleshooting easy

GloCyte Automated CSF Cell Counter

The GloCyte Automated CSF Cell Counter can handle all CSF specimens – even those with clinically relevant low cell counts that fall below the linearity of other automated analyzers. With the ability to detect down to 1 cell/µL and deliver total nucleated cell (TNC) and red blood cell (RBC) results in less than 5-minutes using only 30 µL per test, GloCyte gives hematology labs a reliable and efficient method for automating analysis of all CSF specimens, improving results consistency and turnaround time, compared to the manual hemocytometer method.

Looking for clinical solutions?

Request PricingDownload Brochure
Request a Virtual Demo

Book a 30-minute Zoom session with a product expert

Overview

TIMELY RESULTS YOU CAN COUNT ON

- GloCyte puts your mind at ease by calculating TNC and RBC results for you in cells/µL.
- Quick assay procedure generates results with only 30 µL of sample per test.
- No mandatory background checks are required between samples.

PRODUCTIVITY YOU CAN COUNT ON

- GloCyte uses disposable test cartridges, so there is no carryover between samples and infectious specimens can be processed without worry.
- No more headaches from routine maintenance because GloCyte has no moving parts.
- The proficiency assessment tool confirms new users will obtain results with confidence.
- Test cartridges can be manually marked for keeping track of sample analysis.
- The analyzer’s small footprint makes the most of every inch of valuable lab space.

SIMPLICITY YOU CAN COUNT ON

- GloCyte is easy to operate with everything you need on one screen.
- When dilution is necessary, software guidance leads you through the quickest way to get to the result.
- Interactive software makes troubleshooting easy.
- Customizable field entries provide consistency with terminology currently used in your laboratory.

DATA MANAGEMENT YOU CAN COUNT ON

- Simple search functions make it easy to quickly retrieve results.
- Quality control features include Levey-Jennings charts, password protection, and an audit table. You can also flag aberrant control results and expired materials.
- GloCyte software interfaces with LIS and data is easily exported for statistical analysis.
- Comprehensive patient reports can be printed effortlessly.

Technical Specifications

Sample type Human cerebrospinal fluid (csf)
Assay Parameters Total nucleated cell (TNC) and red blood cell (RBC)
Sample volume 30 µL per assay
Test time 1-2 specimens in under 5 minutes
Power requirement
  • Universal AC/DC power supply: 100 to 240 VAC (50/60 Hz)/1A
  • Instrument: 12 VDC/2A
  • Vacuum Station: 5 VDC/0.5A
Communication USB 2.0 ports
Laser Class 3B, 3O mWatts nominal rating, Class 1 when installed in the instrument with the external enclosure in place
Operating conditions
  • temperature 18°C to 35°C (64°F to 95°F)
  • Humadity 5 to 90% RH, non condensing
Storage temperature
  • GloCyte instrument & vacuum station: -20°C to 60°C (-4°F to 140°F)
  • GloCyte test cartridges 10°C to 40°C (50°F to 104°F)
Dimensions (D x W x H)
  • Instrument 25.5 (H) × 15.3 (W) × 20.4 (D) cm (10.0 × 6.0 × 8.0 inches)
  • Computer 40 (H) × 50 (W) × 20 (D) cm (16 × 20 × 8 inches)
  • Vacuum station 10.8 (H) × 12.1 (W) × 10.8 (D) cm (4.3 × 4.8 × 4.3 inches)
Net weight 18.1 kg (40.0 lbs.)
Shipping weight 24.5 kg (54.0 lbs.)

Associated Products

Supplies & Accessories

111010Test Cartridges (200 pieces)
111011RBC Reagent (3 vials, 1.8 mL each)View
111012TNC Reagent (3 vials, 1.8 mL each)View
111013Low and High Level Controls (1 vial of each level, 3 mL each)View
111076Vacuum Station
111164Sample Preparation Tray
800097Pipette Tips (960 pieces)
802024Vacuum Station O-Ring
80605310 µL Fixed Volume Pipette
80605430 µL Fixed Volume Pipette

Applications

Applications

Busy labs often look to automation to ensure timely sample processing, but analyzing CSF samples – especially those at clinically relevant low cell counts – can be time-consuming and challenging. For labs that want to improve results consistency and turnaround time, there’s an Advanced Solution that meets this need with GloCyte.

Educational Resources

Brochure

GloCyte Automated Cell Counter

Data Sheet

GloCyte Data Sheet

Comparison

A multi-center performance evaluation of the GloCyte system

We are open and continue to provide essential lab supplies during the COVID-19 pandemic. Answers to your FAQ’s can be found here.

Read More
X