“Easy to operate and user friendly. Quick and accurate results. System prompts to enter pertinent specimen information such as color, clarity, tube #, etc. Once trained, the steps are easy to remember.”
The GloCyte Automated CSF Cell Counter can handle all CSF specimens – even those with clinically relevant low cell counts that fall below the linearity of other automated analyzers. With the ability to detect down to 1 cell/µL and deliver total nucleated cell (TNC) and red blood cell (RBC) results in less than 5-minutes using only 30 µL per test, GloCyte gives hematology labs a reliable and efficient method for automating analysis of all CSF specimens, improving results consistency and turnaround time, compared to the manual hemocytometer method.
Looking for clinical solutions?
Book a 30-minute Zoom session with a product expert
“Easy to operate and user friendly. Quick and accurate results. System prompts to enter pertinent specimen information such as color, clarity, tube #, etc. Once trained, the steps are easy to remember.”
Sample type | Human cerebrospinal fluid (csf) |
Assay Parameters | Total nucleated cell (TNC) and red blood cell (RBC) |
Sample volume | 30 µL per assay |
Test time | 1-2 specimens in under 5 minutes |
Power requirement |
|
Communication | USB 2.0 ports |
Laser | Class 3B, 3O mWatts nominal rating, Class 1 when installed in the instrument with the external enclosure in place |
Operating conditions |
|
Storage temperature |
|
Dimensions (D x W x H) |
|
Net weight | 18.1 kg (40.0 lbs.) |
Shipping weight | 24.5 kg (54.0 lbs.) |
111010 | Test Cartridges (200 pieces) | |
111011 | RBC Reagent (3 vials, 1.8 mL each) | View |
111012 | TNC Reagent (3 vials, 1.8 mL each) | View |
111013 | Low and High Level Controls (1 vial of each level, 3 mL each) | View |
111076 | Vacuum Station | |
111164 | Sample Preparation Tray | |
800097 | Pipette Tips (960 pieces) | |
802024 | Vacuum Station O-Ring | |
806053 | 10 µL Fixed Volume Pipette | |
806054 | 30 µL Fixed Volume Pipette |
Busy labs often look to automation to ensure timely sample processing, but analyzing CSF samples – especially those at clinically relevant low cell counts – can be time-consuming and challenging. For labs that want to improve results consistency and turnaround time, there’s an Advanced Solution that meets this need with GloCyte.
Reducing Error Associated with Manual Chamber Counts with the GloCyte Automated Cell Counter for CSF
GloCyte Data Sheet
A multi-center performance evaluation of the GloCyte system
A summary of the features and benefits of GloCyte